Guidelines for Surgical and Interventional Treatment of Valvular Haert Disease( JCS 2012)
文献
501. Hammermeister KE, Sethi GK, Henderson WG, et al. A comparison of outcomes in men 11 years after heart-valve replacement with a mechanical valve or bioprosthesis. Veterans Affairs Cooperative Study on Valvular Heart Disease. N Engl J Med 1993; 328: 1289-1296. 502. Sievers HH, Hanke T, Stierle U, et al. A critical reappraisal of the Ross operation: renaissance of the subcoronary implantation technique? Circulation 2006; 114(1 Suppl): I504-I511. 503. Clark JB, Pauliks LB, Rogerson A, et al. The Ross operation in children and young adults: a fifteen-year, singleinstitution experience. Ann Thorac Surg 2011; 91: 1936-1941. 504. El-Hamamsy I, Eryigit Z, Stevens LM, et al. Long-term outcomes after autograft versus homograft aortic root replacement in adults with aortic valve disease: a randomised controlled trial. Lancet 2010; 376: 524-531. 505. Juthier F, Vincentelli A, Pincon C, et al. Reoperation after the Ross procedure: incidence, management, and survival. Ann Thorac Surg 2012; 93: 598-604. 506. Shrestha BM, Fukushima S, Vrtik M, et al. Partial replacement of tricuspid valve using cryopreserved homograft. Ann Thorac Surg 2010; 89: 1187-1194. 507. O’Brien MF, Harrocks S, Stafford EG, et al. The homograft aortic valve: a 29-year, 99.3% follow up of 1,022 valve replacements. J Heart Valve Dis 2001; 10: 334-344. 508. Yacoub M, Rasmi NR, Sundt TM, et al. Fourteen-year experience with homovital homografts for aortic valve replacement. J Thorac Cardiovasc Surg 1995; 110: 186-193. 509. Joudinaud TM, Baron F, Raffoul R, et al. Redo aortic root surgery for failure of an aortic homograft is a major technical challenge. Eur J Cardiothorac Surg 2008; 33: 989-994. 510. Kitamura S, Yagihara T, Kobayashi J, et al. Mid- to longterm outcomes of cardiovascular tissue replacements utilizing homografts harvested and stored at Japanese institutional tissue banks. Surg Today 2011; 41: 500-509. 511. Burdon TA, Miller DC, Oyer PE, et al. Durability of porcine valves at fifteen years in a representative North American patient population. J Thorac Cardiovasc Surg 1992; 103: 238-251. 512. Jamieson WR, Burr LH, Munro AI, et al. Carpentier-Edwards standard porcine bioprosthesis: a 21-year experience. Ann Thorac Surg 1998; 66 (6 Suppl): S40-S43. 513. Khan SS, Chaux A, Blanche C, et al. A 20-year experience with the Hancock porcine xenograft in the elderly. Ann Thorac Surg 1998; 66(6 Suppl): S35-S39. 514. Borger MA, Ivanov J, Armstrong S, et al. Twenty-year results of the Hancock II bioprosthesis. J Heart Valve Dis 2006; 15: 49-55. 515. David TE, Armstrong S, Maganti M. Hancock II bioprosthesis for aortic valve replacement: the gold standard of bioprosthetic valves durability? Ann Thorac Surg 2010; 90: 775-781. 516. Jamieson WR, Burr LH, Miyagishima RT, et al. Carpentier-Edwards supra-annular aortic porcine bioprosthesis: clinical performance over 20 years. J Thorac Cardiovasc Surg 2005; 130: 994-1000. 517. Jamieson WR, Riess FC, Raudkivi PJ, et al. Medtronic Mosaic porcine bioprosthesis: assessment of 12-year performance. J Thorac Cardiovasc Surg 2011; 142: 302-307. 518. Riess FC, Cramer E, Hansen L, et al. Clinical results of the Medtronic Mosaic porcine bioprosthesis up to 13 years. Eur J Cardiothorac Surg 2010; 37: 145-153. 519. Jamieson WR, Lewis CT, Sakwa MP, et al. St Jude Medical Epic porcine bioprosthesis: results of the regulatory evaluation. J Thorac Cardiovasc Surg 2011; 141: 1449-1454. 520. Maitland A, Hirsch GM, Pascoe EA. Hemodynamic performance of the St. Jude Medical Epic Supra aortic stented valve. J Heart Valve Dis 2011; 20: 327-331. 521. Cosgrove DM, Lytle BW, Gill CC, et al. In vivo hemodynamic comparison of porcine and pericardial valves. J Thorac Cardiovasc Surg 1985; 89: 358 -368. 522. Aupart MR, Mirza A, Meurisse YA, et al. Perimount pericardial bioprosthesis for aortic calcified stenosis: 18-year experience with 1133 patients. J Heart Valve Dis 2006; 15: 768-775. 523. Aupart MR, Sirinelli AL, Diemont FF, et al. The last generation of pericardial valves in the aortic position: tenyear follow-up in 589 patients. Ann Thorac Surg 1996; 61: 615-620. 524. Ayegnon KG, Aupart M, Bourguignon T, et al. A 25-year experience with Carpentier-Edwards Perimount in the mitral position. Asian Cardiovasc Thorac Ann 2011; 19: 14-19. 525. Banbury MK, Cosgrove DM, III, White JA, et al. Age and valve size effect on the long-term durability of the Carpentier Edwards aortic pericardial bioprosthesis. Ann Thorac Surg 2001; 72: 753-757. 526. Banbury MK, Cosgrove DM, III, Lytle BW, et al. Longterm results of the Carpentier-Edwards pericardial aortic valve: a 12-year follow-up. Ann Thorac Surg 1998; 66(6 Suppl): S73-S76. 527. Cosgrove DM, Lytle BW, Taylor PC, et al. The Carpentier-Edwards pericardial aortic valve. Ten-year results. J Thorac Cardiovasc Surg 1995; 110: 651 -662. 528. Eric Jamieson WR, Marchand MA, Pelletier CL, et al. Structural valve deterioration in mitral replacement surgery: comparison of Carpentier-Edwards supra-annular porcine and perimount pericardial bioprostheses. J Thorac Cardiovasc Surg 1999; 118: 297-304. 529. Jamieson WR, Germann E, Aupart MR, et al. 15-year comparison of supra-annular porcine and PERIMOUNT aortic bioprostheses. Asian Cardiovasc Thorac Ann 2006; 14: 200-205. 530. Marchand M, Aupart M, Norton R, et al. Twelve-year experience with Carpentier-Edwards PERIMOUNT pericardial valve in the mitral position: a multicenter study. J Heart Valve Dis 1998; 7: 292-298. 531. McClure RS, Narayanasamy N, Wiegerinck E, et al. Late outcomes for aortic valve replacement with the Carpentier-Edwards pericardial bioprosthesis: up to 17-year follow-up in 1,000 patients. Ann Thorac Surg 2010; 89: 1410-1416. 532. Dalmau MJ, Gonzalez-Santos JM, Blazquez JA, et al. Hemodynamic performance of the Medtronic Mosaic and Perimount Magna aortic bioprostheses: five-year results of a prospectively randomized study. Eur J Cardiothorac Surg 2011; 39: 844-852. 533. Wagner IM, Eichinger WB, Bleiziffer S, et al. Influence of completely supra-annular placement of bioprostheses on exercise hemodynamics in patients with a small aortic annulus. J Thorac Cardiovasc Surg 2007; 133: 1234-1241. 534. Wyss TR, Bigler M, Stalder M, et al. Absence of prosthesispatient mismatch with the new generation of Edwards stented aortic bioprosthesis. Interact Cardiovasc Thorac Surg 2010; 10: 884-887. 535. The Italian study on the Mitroflow postoperative results (ISTHMUS): a 20-year, multicentre evaluation of Mitroflow pericardial bioprosthesis. Eur J Cardiothorac Surg 2011; 39: 18-26. 536. Conte J, Weissman N, Dearani JA, et al. A North American, prospective, multicenter assessment of the Mitroflow aortic pericardial prosthesis. Ann Thorac Surg 2010; 90: 144-152. 537. Kon ND, Cordell AR, Adair SM, et al. Aortic root replacement with the freestyle stentless porcine aortic root bioprosthesis. Ann Thorac Surg 1999; 67: 1609-1615. 538. Bach DS, Kon ND, Dumesnil JG, et al. Eight-year results after aortic valve replacement with the Freestyle stentless bioprosthesis. J Thorac Cardiovasc Surg 2004; 127: 1657-1663. 539. Deleuze PH, Fromes Y, Khoury W, et al. Eight-year results of Freestyle stentless bioprosthesis in the aortic position: a single-center study of 500 patients. J Heart Valve Dis 2006; 15: 247-252. 540. Melina G, De RF, Gaer JA, et al. Mid-term pattern of surviva l , hemodynamic performance and rate of complications after medtronic freestyle versus homograft full aortic root replacement: results from a prospective randomized trial. J Heart Valve Dis 2004; 13: 972-975. 541. Auriemma S, D’Onofrio A, Brunelli M, et al. Long-term results of aortic valve replacement with Edwards Prima Plus stentless bioprosthesis: eleven years’ follow up. J Heart Valve Dis 2006; 15: 691-695. 542. Jin XY, Ratnatunga C, Pillai R. Performance of Edwards prima stentless aortic valve over eight years. Semin Thorac Cardiovasc Surg 2001; 13(4 Suppl 1): 163-167. 543. Burr LH, Jamieson WR, Munro AI, et al. Structural valve deterioration in elderly patient populations with the Carpentier-Edwards standard and supra -annular porcine bioprostheses: a comparative study. J Heart Valve Dis 1992; 1: 87-91. 544. David TE, Ivanov J, Armstrong S, et al. Late results of heart valve replacement with the Hancock II bioprosthesis. J Thorac Cardiovasc Surg 2001; 121: 268-277. 545. Jamieson WR, Burr LH, Tyers GF, et al. Carpentier-Edwards standard and supra-annular porcine bioprostheses: 10 year comparison of structural valve deterioration. J Heart Valve Dis 1994; 3: 59-65. 546. Pelletier LC, Carrier M, Leclerc Y, et al. Influence of age on late results of valve replacement with porcine bioprostheses. J Cardiovasc Surg (Torino) 1992; 33: 526-533. 547. Chang BC, Lim SH, Yi G, et al. Long-term clinical results of tricuspid valve replacement. Ann Thorac Surg 2006; 81: 1317-1323, discussion. 548. Dalrymple-Hay MJ, Leung Y, Ohri SK, et al. Tricuspid valve replacement: bioprostheses are preferable. J Heart Valve Dis 1999; 8: 644-648. 549. Kawachi Y, Tominaga R, Hisahara M, et al. Excellent durability of the Hancock porcine bioprosthesis in the tricuspid position. A sixteen-year follow-up study. J Thorac Cardiovasc Surg 1992; 104: 1561-1566. 550. Iturbe-Alessio I, Fonseca MC, Mutchinik O, et al. Risks of anticoagulant therapy in pregnant women with artificial heart valves. N Engl J Med 1986; 315: 1390-1393. 551. Wong V, Cheng CH, Chan KC. Fetal and neonatal outcome of exposure to anticoagulants during pregnancy. Am J Med Genet 1993; 45: 17-21. 552. Cleuziou J, Horer J, Kaemmerer H, et al. Pregnancy does not accelerate biological valve degeneration. Int J Cardiol 2010; 145: 418-421. 553. Elkayam U, Bitar F. Valvular heart disease and pregnancy: part II: prosthetic valves. J Am Coll Cardiol 2005; 46: 403-410. 554. Mihaljevic T, Paul S, Leacche M, et al. Valve replacement in women of childbearing age: influences on mother, fetus and neonate. J Heart Valve Dis 2005; 14: 151-157. 555. North RA, Sadler L, Stewart AW, et al. Long-term survival and valve-related complications in young women with cardiac valve replacements. Circulation 1999; 99: 2669-2676. 556. Kawamata K, Neki R, Yamanaka K, et al. Risks and pregnancy outcome in women with prosthetic mechanical heart valve replacement. Circ J 2007; 71: 211-213. 557. Shannon MS, Edwards MB, Long F, et al. Anticoagulant management of pregnancy following heart valve replacement in the United Kingdom, 1986 -2002. J Heart Valve Dis 2008; 17: 526-532. 558. Sillesen M, Hjortdal V, Vejlstrup N, et al. Pregnancy with prosthetic heart valves - 30 years’ nationwide experience in Denmark. Eur J Cardiothorac Surg 2011; 40: 448-454. 559. Boning A, Boedeker RH, Rosendahl UP, et al. Long-term results of mechanical and biological heart valves in dialysis and non-dialysis patients. Thorac Cardiovasc Surg 2011; 59: 454-459. 560. Umezu K, Saito S, Yamazaki K, et al. Cardiac valvular surgery in dialysis patients: comparison of surgical outcome for mechanical versus bioprosthetic valves. Gen Thorac Cardiovasc Surg 2009; 57: 197-202.